Per 29 cfr 1910 101 b the in plant handling storage and utilization of all compressed gas cylinders must be in accordance with cga pamphlet p 1 standard for safe handling of compressed gases in containers revised march 23 2015.
Osha compressed gas cylinder storage requirements.
Other sources of information regarding storage of lp gas cylinders can be obtained from osha standard 29 cfr 1910 101 which covers general requirements regarding compressed gases.
1 the standard further states in 1910 101 b that the in plant handling storage and utilization of all compressed gases in cylinders.
Keep the tanks away from the sun flames sparks and areas that reach and exceed 125 degrees fahrenheit.
That is storing these cylinders with other flammables inside flammable materials storage cabinets would not be in compliance with osha s regulations.
Here are the compressed gas cylinder storage tips.
The required fire extinguisher must be located no more than 50 feet from the storage location.
To prevent fires and explosions osha requires workplace gas cylinder storage at least 20 feet away from highly combustible materials and oxygen cylinders shall sit completely away from anything combustible especially oils and greases.
Gas cylinders should be properly secured at all times to prevent tipping falling or rolling.
Include firewalls for cylinders with contents that pose different types of hazards.
Compressed gases the in plant handling storage and utilization of all compressed gases in cylinders portable tanks rail tankcars or motor vehicle cargo tanks shall be in accordance with compressed gas association pamphlet p 1 1965 which is incorporated by reference as specified in sec.
1910 253 b 4 iv.
Oxygen cylinders in storage shall be separated from fuel gas cylinders or combustible materials especially oil or grease a minimum distance of 20 feet 6 1 m or by a noncombustible barrier at least 5 feet 1 5 m high having a fire resistance rating of at least one half hour.
Therefore since the cga pamphlet is incorporated by reference into osha s standard your interpretation regarding the storage of propane and ether gas cylinders with other flammables is correct.
Oxidizers should not rest within twenty feet of gases which are flammable.
Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.
12 the in plant handling storage and utilization of all compressed gases in cylinders portable tanks rail tankcars or motor vehicle cargo tanks shall be in accordance with compressed gas association pamphlet p 1 1965.
1926 350 a 10 oxygen cylinders in storage shall be separated from fuel gas cylinders or combustible materials especially oil or grease a minimum distance of 20 feet 6 1 m or by a noncombustible barrier at least 5 feet 1 5 m high having a fire resistance rating of at least one half hour.