Complying with osha lighting standards.
Osha temporary lighting for construction.
The occupational safety and health administration s construction regulations specifically 29 cfr 1926 401 require that lights shall be equipped with guards unless the bulb is deeply recessed.
To further conform to osha temporary lights must have exposed noncurrent carrying metal parts properly grounded and temporary lighting stringers or streamers arranged to avoid overloading.
This is in response to your recent inquiry requesting a clarification of standards for temporary wiring and temporary lighting in heavy construction.
We know that compliance with osha lighting standards is about more than protecting your bottom line.
Osha standards state that a minimum of 5 foot candles should be used to illuminate corridors warehouses hallways general construction areas and exit ways.
09 16 1981 1926 405 b 2 electrical standard requirements concerning covers for electrical pull boxes junction boxes and fittings.
Table d 3 minimum illumination intensities in foot candles.
The july 17 1980 letter from mr.
It is osha s position that temporary lighting strings used on construction sites which do not.
The one exception is that temporary electrical installations of more than 600 volts may only be used in emergency situations tests or temporary construction activities.
1926 405 a 2 ii j temporary lighting strings used on construction sites.
Ericson addresses issues raised by mr.
Ericson in a letter to osha i e what are the requirements that must be met for temporary lighting strings with non heavy duty cord to acceptable to osha.
Temporary wiring shall be removed immediately upon completion of construction or the purpose for which the wiring was installed.
Subject temporary lighting construction standards standards policy memorandum 81 328 29 cfr 1926 401 j 2 and 1926 402 an opinion of whether use of romex for temporary lighting on construction jobs is a citable hazard has been requested.
Construction areas ramps runways corridors offices shops and storage areas shall be lighted to not less than the minimum illumination intensities listed in table d 3 while any work is in progress.
In the case of emergencies for those working underground headlights are required.
Explosion proof self contained lights the employer shall provide and ensure that each employee uses only explosion proof self contained temporary and portable lights approved for hazardous conditions by a nationally recognized testing laboratory nrtl in any area that the atmosphere is determined to contain a concentration of flammable vapors that are at or above 10 percent of the lower.
Occupational safety health administration.